Description
| Parameter | Specification |
|---|
| Model | EATB-L4E1 |
| Load Cell Inputs | 4 or 6 Load Cells (Parallel Connection) |
| Input Type | mV Signal from Strain Gauge Load Cells (350Ω–1000Ω) |
| Summing Type | Passive Summing with Individual Trimming |
| Trim Resistors | Multi-turn potentiometers for each load cell |
| Shielding | Independent Shield Terminals with Grounding |
| Excitation Voltage Range | 5 VDC to 15 VDC (pass-through from controller) |
| Output | Summed Signal Output to Indicator/Transmitter |
| Surge Protection | Optional Transient Voltage Suppression (TVS) Diodes |
| Cable Entry | IP-rated Cable Glands (PG9/PG11/PG13.5) |